Information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Number | GTM46161-16V.V-USB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | GTM46161-16V.V-USB, Medical Power Supply, 60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 16 Watts, Power rating with convection cooling (W) , 5-5.5V in 0.1V increments, Approvals: CCC RCM UL 1310 ETL CB 60601-1 S-Mark IEC/EN 60601-1 S-Mark 60950 EAC CB 62368 Double Insulation Ukraine RoHS China RoHS Level VI WEEE ETL CE FCC CAN ICES-3 PSE IP20 CB 60950 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM46161/ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | https://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FiXUuEAN | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000FiXUuEAN | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Wall Plug-in | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Category | Medical Power Supply | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.45A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 16 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-5.5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | VI | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | Indoor Use | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 41.0 x 71.0 x 31.5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | A) ELECTRICAL SPECIFICATIONS: 1. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac 2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60 Hz 3.Output Regulation: +/- 5% measured at the end of a 1.2 meter USB cordset employing #20 Gauge conductors (RFP RFI-50856) The longest cable GlobTek recommends to be used with this product is USB cord GlobTek PNs USBA1M2MICROB20(R) and USBC1M0USBA(R), 1.2 Meters for best voltage regulation performance. (RFP RFI-20435-3) 4. Line Voltage Regulation: +/- 3% typical 5. Output Ripple (Vp-p): 150mV Ripples shall be measured with a 47uF electrolytic capacitor paralleled with a high-frequency 0.1uF ceramic capacitor across the output. The oscilloscope's bandwidth shall be set to 20MHz. 6. Turn-On/Turn-Off Overshoot: 5% maximum, 500 us maximum recovery time for 25% step load. 7. Turn-On Delay: 3000mS MAX at 115VAC Full Load 8. Hold-Up Time: 8mS Min at 100VAC Full Load 9. Inrush Current: No damage. On power when switching on/off repeatedly under any condition. 10. Switching Frequency: 66.5 KHz typical 11. Average Efficiency: 78.7% Min.(CEC&DOE Level VI Compliant), 79.0% Min. (ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant) 12. Input Power(no load): < 0.1W < 0.1W, < 0.075W (ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant) B) PROTECTION 1. Over-Voltage: Output shut down and auto restart 2. Over Temperature Protection: Output shut down and auto restart 3. Short Circuit Protection Output shut down and auto restart 4 Over Load Protection Output shut down and auto restart 5. Input Protection: Input line fusing 6. ESD: 8 kV Contact/20kV Air Discharge C) SAFETY 1. Dielectric Withstand Voltage: 4000Vac or 5656Vdc 10mA 1 minute 2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured 3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition) 4. Means of Protection: 2 x MOPP 5. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 D) EMC 1. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 2. Line Frequency Harmonics EN61000-3-2, Class A 3. Voltage Fluctuations/Flicker EN61000-3-3 4. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 8kV Contact Discharge, 15kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-2700MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 2kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, NA Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 1. MTBF: 200,000 hours @ 25°C ambient temperature 2. Operating Temperature: 0°C to 40°C ambient temperature 3. Humidity: 0% to 95% relative humidity 4. Storage Temperature: -40°C to 80°C F) ENCLOSURE 1. Housing: High impact plastic, 94V0 polycarbonate, non-vented 2. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 210 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 74 x 35 x 42 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 544 x 375 x 151 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 14.8 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 28.5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 17.5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Blade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf Video: Q-Blade Style Instruction Video INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified 01. United States / Canada / Japan NEMA 1-15P/IEC PLUG A[WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R) Kits 01. Q-KIT: 1,2,3,4 above | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Configuration | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Popular Products (Stock items) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|