Model NumberGTM91120-30VV-FW
DescriptionGTM91120-30VV-FW, ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 CLASS II or EQUIVALENT, Output Rating: 30 Watts, 5-48V in 0.1V increments, Approvals: WEEE VCCI SIQ SIQ Level V FCC CE CE CB EN/IEC 60335-1 CB CB cRUus cRUus CE Double Insulation ETL CB RoHS 2 China RoHS
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000HWWF4EAP
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000HWWF4EAP
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000HWWF4EAP
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)101.6x50.8x22.30
EnclosureUser-added image
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM91120-3007.5-2.5-FW 5420 RFQ
GTM91120-3007.5-1.5-FW 63.7522.5 RFQ
GTM91120-3010.5-1.5-FW 92.7724.93 RFQ
GTM91120-3010.5-1.4-FW 9.13.330.03 RFQ
GTM91120-3014.5-2.5-FW 122.530 RFQ
GTM91120-3019.5-4.5-FW 15230 RFQ
GTM91120-3019.5-1.5-FW 181.6629.88 RFQ
GTM91120-3024-FW 241.2530 RFQ
GTM91120-3036-FW 360.8329.88 RFQ
GTM91120-3048-FW 480.62530 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60 Hz
3. Output power (rated): 30Watts max
Note: Refer to Power Supply information on page 2 for the corresponding rated output power for the specific output voltage.
4. Output Regulation: +/- 5% measured at the output connector
5. Line Voltage Regulation: +/- 2% typical measured at full load
6. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
Optional low ripple option available (RFP4579)
7. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
8. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
9 Hold-Up Time: 8mS typical @ nominal input voltage and full load
10. Inrush Current: 60A maximum cold start @ 240Vac input
11. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)



D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Humidity: 0% to 90% relative humidity
3. Storage Temperature: -10°C to 80°C
4. Operating Temperature: 0°C to 40°C ambient temperature
5. Cooling: Convection

E) ENCLOSURE
1. Housing: Open Frame
2. Size: 101.6 x 50.8 x 22.3 mm +/-1.0 mm
3. Markings: Label and/or Pad Printed
Derating Curve
Qty (ea.)/Carton72
Individual Box/Gift Box Size (mm)110*60*40
Individual Box/Gift Box Colorwhite
Master Carton Size (mm)375 x 345 x 200
Gross Weight (kg)
Label Width (mm)20.0
Label Height (mm)15.0
Input Configuration
Description5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 CLASS II or EQUIVALENT
User-added image




Approvals
LogoDescription
No Logo ApplicableCB Report to ETL 60601-1, 3rd Edition+60601-1-11

No Logo Applicable

CB report 60950-1 2nd Ed

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added image  CE Mark: tested to comply with EN 60601-1-2:2007 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added imageIEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: Gen. Req. for Basic Safety &Essential Perf.- Collateral Standard - Req. for Medical Elec. Equip. & Medical Elec.Systems Used in the Home Healthcare Environment
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
cRUus Registered E170507 CSA C22.2 No. 60950-1 2nd Ed.
User-added imagecRUus UL Recognized Component E172861 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
No LogoDesigned to meet EN 60601-1:2006 + A11:2011 +A1:2013 3rd Edition
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image
FCC PART 15 CLASS B
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageRCM certificate SAA150575; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
Serial Number Information
User-added image
IEC/EN60335-1
SIQ IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 volts
User-added image
IEC/EN60601-1
SIQ Mark License EN60601-1, 3rd edition
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
127643122.5(4) Position Terminal Block
109064122.5P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
180410152.0P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
162989152.0P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
226280241.25P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
18036954P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
17131254P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
1838649.13.3P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR

Solicitud de Información