GT-G3067P350VV-X.X-C Enclosed-Metal ICT/ITE Power Supply

GT-G3067P350VV-X.X-C
GT-G3067P350VV-X.X-C, ICT/ITE Power Supply, Enclosed-Metal, Single Output Power supply Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), Terminal Block, Output Rating: 360 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: WEEE; Ukraine; GOST-R; CE; China RoHS; RoHS; PSE; VCCI; cULus; Class I;GT-G3067P350VV-X.X-C, ICT/ITE Power Supply, Enclosed-Metal, Single Output Power supply Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), Terminal Block, Output Rating: 360 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: WEEE; Ukraine; GOST-R; CE; China RoHS; RoHS; PSE; VCCI; cULus; Class I;
Information
Model NumberGT-G3067P350VV-X.X-C
Agency Documentshttp://www.globtek.info/certs/GT-G3067PWWWVV-X.X-C/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0Oa000000MEY5zEAH
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for MedicalContact GlobTek for more information
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0Oa000000MEY5zEAH
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MEY5zEAH
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MEY5zEAH
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeEnclosed-Metal
TechnologySingle Output Power supply Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz)
Max Input Current (A)4.0A / 115VAC, 2.0A / 230VAC
Max Output Power Rating (W)360
Output Voltage Range (V)5-48
EfficiencyN/A
Ingress ProtectionIPX0
Size (mm)105x41x199
EnclosureUser-added image
User-added image
User-added image
User-added image
User-added image
 
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
GT-G3067P35005-C*560300
GT-G3067P35012-C*1230360
GT-G3067P35015-C*1524360
GT-G3067P35024-C*2415360
GT-G3067P35048-C*487.5360
* (Final ordering #/Part No to be defined)
Specifications
Features:
Universal AC input / Full range
Built in active PFC function, PF > 0.90
+5V / 0.3A auxiliary output
150% Peak load Capability Constant current limit Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure


ELECTRICAL SPECIFICATIONS:
Input and output
Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
De-rating may apply in low input voltage.
Frequency Range: 47 ~ 63Hz
Power Factor (Typ.): 0.98 / 230VAC, 0.99 / 115VAC at ful load
Efficiency (Typ.): 83% - 93%
AC Current (Typ.) 4.0A / 115VAC, 2.0A / 230VAC
Inrush Current (Typ.) 27A / 115VAC, 54A / 230VAC
Leakage Current: < 1.0mA / 240VAC
Ripple & Noise (Max.): <1% (mVp-p), according to the rated Output Voltage
Voltage Adj. Range ±10% Typical adjustment by potentiometer
Voltage Tolerance ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation.
Line Regulation ±0.5%
Load Regulation ±0.5%
Setup, Rise Time 800ms, 60ms at full load
Hold Up Time (Typ.) 16ms / 230VAC at full load

Protection
Over Load Hiccup mode: when the rated output power is within 105 ~ 150% for more than 3secs.
Constant current limit: > 150% rated power / short circuit
Auto-recovery: If O/P drop to 40% of the rated output voltage, PSU will shut down and auto-recover
5times (If fault condition remains after 5times recovery, PSU will shut down. User must re-power on to recover)

Over Voltage Variable OVP, Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Over Temperature By detecting primary and secondary heat sink.
Protection type: Shut down o/p voltage (Auto recovers automatically after temperature goes down)

Function
Auxiliary Power 5V / 0.3A (±3%)
Remote ON / OFF Control External switch or NPN Transistor to turn ON / OFF
Power OK Signal Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.

Environment
Working Temp. -20 ~ +70°C (Refer to output load de-rating curve)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp. & Humidity -40 ~ +85°C, 10 ~ 95% RH
Temp. Coefficient ±0.02% / °C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 1G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6-2007

Safety & EMC
Safety Standards Certified UL 60950-1; EN 60950-1
Withstand Voltage I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC), 1min
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
EMI Conduction & Radiation Certified EN 55022; EN 61000-6-3
Harmonic Current Certified EN 61000-3-2; EN 61000-3-3
EMS Immunity Certified EN 61204-3; EN 55024; EN 61000-6-1, IEC 61000-4-2, 3, 4, 5, 6, 8, 11

Others
MTBF 74.56K HRS Certified MIL-HDBK-217F
Cooling Load and temperature control fan
Dimension (WxHxH) 105x41x199 mm / 4.134x1.614x7.835 inch
Packing 1.1kg; 18pcs / 20.1kg / 1.02CUFT
Derating CurveUser-added image
 
Qty (ea.)/Carton18
Individual Box/Gift Box Size (mm)220*110*45
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)TBD
Gross Weight (kg)20.1
Label Width (mm)90.0
Label Height (mm)30.0
Input Configuration
DescriptionTerminal Block
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: https://www.globtek.com/r2/Szj4Vb
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added imageIndoor Use Only - Mark is on the label or Molded in the case

User-added image  
CE Certification
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
nullClass I Earth Ground
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL60950-1, cULus to UL 60950-1 E170507
Request Info